• Home
  • About us
  • Services
    • Radiation Measurement
    • Calibration and Maintenance
  • Products
    • X-Ray
      • RaySafe
      • Phantoms
        • Radiographic & Fluoroscopic
        • Mammography
        • Dentistry
        • Computer Tomography
        • Magnetic Resonance
        • Radiotherapy
        • Nuclear Medicine
        • Software
        • Non-Destructive Testing
        • Other Test Devices
      • Dental
    • Remote Sensing
      • Airborne Systems
      • Ground Truthing
    • Spectral Imaging
      • Spectral Cameras
      • Spectrographs
      • Systems & Accessories
    • Spectroradiometry
      • Hand held
      • Systems
    • Luminance Cameras
      • LMK mobile advanced
      • LMK 5 Luminance Camera
      • LMK 5 color
      • L20 Tunnel Entrance Sensor
    • Optical Radiation Standard
      • Sphere Standard
      • Lamp Standard
      • L3-standard Luminance, Luminous flux, Luminous Intensity
    • Near-field Goniophotometer
    • L20 Tunnel Lighting Control
      • Illuminance Sensors
      • Lighting Control Systems
    • Lux Meters
    • Photometers
  • Partners
  • Vacancies
  • Contact
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Products Near-field Goniophotometer RiGO801 - 300

Spectra Partners

Near-field Goniophotometer


This free-standing type C goniophotometer has a maximum measuring volume of a diameter of 300 mm, and is well suited for measurement objects ranging from LEDs up to small luminaires. The measuring camera and the other sensors being mounted on two axes linked with each other are moved on a spherical surface around the stationary object to be measured.
 
The goniometer is mounted in an external frame in an entirely pivotable manner so that vertical just as horizontal burning positions can be set. This is particularly important for measuring automotive lamps as a stable horizontal burning position is urgently necessary here.
 
The high accuracy of the ray data measured allows the ray data measurement of light sources from the size of a power LED on (chip surface area from approx. 1x1 mm² on). The luminous intensity distribution and the luminous flux of much smaller light sources can still be measured as the measurement will then be carried out by the photometer in the far-field mode.
 

Basic technical parameters

Size of the device under test: ≤ 280 mm (diameter of light-emitting surface)
≤ 300 mm (outside diameter)
Required space: LxWxH = ca.2000 x 1600 x 2200 mm³
Movement: goniometer with two coupled axes
Measuring position: stationary, burning position hanging, upright or horizontal
Positioning accuracy of the ray data: < 0.05 mm

Products

X-Ray
Remote Sensing
Spectral Imaging
Spectroradiometry
Luminance Cameras
Optical Radiation Standards
Near-Field Goniophotometer
Tunnel Lighting
Lux Meters
Photo Meters
 

Services

Radiation Measurement
Calibration and Maintenance

 

SpectraPartners
Wateringweg 113, 2031 EG Haarlem
Tel +31 23 544 11 64
Dit e-mailadres wordt beveiligd tegen spambots. JavaScript dient ingeschakeld te zijn om het te bekijken.
Tweets door @spectrapartner

webcreation: Free Design