• Home
  • About us
  • Services
    • Radiation Measurement
    • Calibration and Maintenance
  • Products
    • X-Ray
      • RaySafe
      • Phantoms
        • Radiographic & Fluoroscopic
        • Mammography
        • Dentistry
        • Computer Tomography
        • Magnetic Resonance
        • Radiotherapy
        • Nuclear Medicine
        • Software
        • Non-Destructive Testing
        • Other Test Devices
      • Dental
    • Remote Sensing
      • Airborne Systems
      • Ground Truthing
    • Spectral Imaging
      • Spectral Cameras
      • Spectrographs
      • Systems & Accessories
    • Spectroradiometry
      • Hand held
      • Systems
    • Luminance Cameras
      • LMK mobile advanced
      • LMK 5 Luminance Camera
      • LMK 5 color
      • L20 Tunnel Entrance Sensor
    • Optical Radiation Standard
      • Sphere Standard
      • Lamp Standard
      • L3-standard Luminance, Luminous flux, Luminous Intensity
    • Near-field Goniophotometer
    • L20 Tunnel Lighting Control
      • Illuminance Sensors
      • Lighting Control Systems
    • Lux Meters
    • Photometers
  • Partners
  • Vacancies
  • Contact
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Technical quality, warranty and service
Products Near-field Goniophotometer RiGO801 - 600

Spectra Partners

Near-field Goniophotometer


This free-standing type C goniophotometer has a maximum measuring volume of a diameter of 600 mm and is well suited for measurement objects ranging from LEDs to small luminaires. The measuring camera and the other sensors mounted on two axes linked with each other are moved on a spherical surface around the stationary object to be measured.
 
The high accuracy of the ray data measured (< 0.1 mm) allows the ray data measurement of light sources of a size from a power LED on (chip surface area from approx. 2x2 mm² on). The luminous intensity distribution and the luminous flux of smaller light sources can still be measured as the measurement will be carried out by the photometer in the far-field mode.
 

Basic technical parameters

Size of the device under test: ≤ 550 mm (diameter of light-emitting surface)
≤ 600 mm (outside diameter)
Required space: LxWxH = ca.2000 x 1600 x 2200 mm³
Movement: goniometer with two coupled axes
Measuring position: stationary, burning position hanging
Positioning accuracy of the ray data: < 0.1 mm

Products

X-Ray
Remote Sensing
Spectral Imaging
Spectroradiometry
Luminance Cameras
Optical Radiation Standards
Near-Field Goniophotometer
Tunnel Lighting
Lux Meters
Photo Meters
 

Services

Radiation Measurement
Calibration and Maintenance

 

SpectraPartners
Wateringweg 113, 2031 EG Haarlem
Tel +31 23 544 11 64
Dit e-mailadres wordt beveiligd tegen spambots. JavaScript dient ingeschakeld te zijn om het te bekijken.
Tweets door @spectrapartner

webcreation: Free Design